EPS 031 PRO LAMBDA SUPER
EPS graphite panels produced by foaming polystyrene and intended for thermal insulation of walls, including facade insulation.
Product features:
- Code of designation: EPS EN 13163 T(1)-L(2)-W(2)- Sb(5)-P(5)-BS115-DS(N)2-DS(70,-)2-TR100,
- Declared thermal conductivity coefficient λD ≤ 0,031 (W/(mK),
- Standards dimensions tof the panel 1000 x 500 mm. (untypical dimensions on request.),
- Panel thickness: 10 – 500 mm,
- Panels can be produced with straight or milled edges.
APPLICATION OF EPS 031 PRO LAMBDA SUPER

EPS 031 PRO LAMBDA polystyrene panels applied in insulations which require shifting of extensive mechanical load, among others.:
- Insulation of walls in external thermal insulation composite systems (ETICS) (light-wet method),
- Insulation of multilayer walls with a ventilated or non-ventilated air gap,
- Insulation of framed walls with cladding,
- iInsulation of ceilings from below,
- Insulation of floors between joists,
- Insulation of expansion joints.
Due to the increased heat absorption of EPS 031 PRO LAMBDA SUPER polystyrene panels, it is recommended that before fixing:
- sand the panels with special grinders on the glued side,
- protect both the substrate and the polystyrene panels from sunlight.
In order to protect the polystyrene panels from direct sunlight during insulation work, it is recommended to use scaffolding nets.
details
PANELS TECHNICAL SPECIFICATION EPS 031 PRO LAMBDA
Properties | Class | Required |
Thickness | T(1) | ±1 mm |
Length | L(2) | ±2 mm |
Width | W(2) | ±2 mm |
Rectangularity | Sb(5) | ±5 mm |
Flatness | P(5) | ±5 mm |
Bending strength | BS115 | ≥115 kPa |
Dimensional stability under constant normal laboratory conditions | DS(N)2 | ±0,2% |
Dimensional stability under specific temperature and humidity conditions | DS(70,-)2 | ≤2% |
Tensile strength perpendicular to faces | TR100 | ≥ 100 kPa |
Reaction-to-fire class | E | |
Declared thermal conductivity coefficient λD | ≤0,031(W/(mK) |
TABLE OF THERMAL RESISTANCE EPS 031 Pro Lamba
Panel thickness (mm) | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
RD(m²K/W) | 0,30 | 0,60 | 0,95 | 1,25 | 1,60 | 1,90 | 2,25 | 2,55 | 2,90 | 3,20 |
Panel thickness (mm) | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
RD(m²K/W) | 3,50 | 3,85 | 4,15 | 4,50 | 4,80 | 5,15 | 5,45 | 5,80 | 6,10 | 6,45 |
Panel thickness (mm) | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD(m²K/W) | 6,75 | 7,05 | 7,40 | 7,70 | 8,05 | 8,35 | 8,70 | 9,00 | 9,35 | 9,65 |