Home 9 Expanded polystyrene 9 EPS 032 PRO LAMBDA STANDARD

EPS 032 PRO LAMBDA STANDARD

EPS graphite panels produced by foaming polystyrene and intended for thermal insulation of walls, including facade insulation.

Product features:

  • Code of designation: EPS EN 13163 T(1)-L(2)-W(2)-Sb(5)-P(5)-BS75-DS(N)2-DS(70,-)2-TR80,
  • Declared thermal conductivity coefficient λD ≤ 0,032 (W/(mK),
  • Standards dimensions tof the panel 1000 x 500 mm. (untypical dimensions on request.),
  • Panel thickness: 10 – 500 mm,
  • Panels can be produced with straight or milled edges.

APPLICATION OF EPS 032 PRO LAMBDA STANDARD

Insulating a building with polystyrene foam
Expanded polystyrene EPS 032 PRO LAMBDA STANDARD panels are used for insulation applications requiring the transfer of small mechanical loads, including:

  • Insulation of walls in external thermal insulation composite systems (ETICS) (light-wet method),
  • Insulation of multilayer walls with a ventilated or non-ventilated air gap,
  • Insulation of framed walls with cladding,
  • Insulation of ceilings from below,
  • Insulation of floors between joists,
  • Insulation of expansion joints.
Due to the increased heat absorption of EPS 032 PRO LAMBDA STANDARD polystyrene panels, it is recommended that before fixing:

  • sand the panels with special grinders on the glued side,
  • protect both the substrate and the polystyrene panels from sunlight.

In order to protect the polystyrene panels from direct sunlight during insulation work, it is recommended to use scaffolding nets.

details

PANELS TECHNICAL SPECIFICATION EPS 032 PRO LAMBDA STANDARD

Properties Class Required
Thickness T(1) ±1 mm
Length L(2) ±2 mm
Width W(2) ±2 mm
Rectangularity Sb(5) ±5 mm
Flatness P(5) ±5 mm
Bending strength BS75 ≥75 kPa
Dimensional stability under constant normal laboratory conditions DS(N)2 ±0,2%
Dimensional stability under specific temperature and humidity conditions DS(70,-)2 ≥2%
Tensile strength perpendicular to faces TR80 ≥ 80 kPa
Reaction-to-fire class E
Declared thermal conductivity coefficient λD ≤0,032(W/(mK)

TABLE OF THERMAL RESISTANCE EPS 032 PRO LAMBDA STANDARD

Panel thickness (mm) 10 20 30 40 50 60 70 80 90 100
RD(m²K/W) 0,30 0,60 0,90 1,25 1,55 1,85 2,15 2,50 2,80 3,10
Panel thickness (mm) 110 120 130 140 150 160 170 180 190 200
RD(m²K/W) 3,40 3,75 4,05 4,35 4,65 5,00 5,30 5,60 5,90 6,25
Panel thickness (mm) 210 220 230 240 250 260 270 280 290 300
RD(m²K/W) 6,55 6,85 7,15 7,50 7,80 8,10 8,40 8,75 9,05 9,35