EPS 035 TERRA AQUA ECO
EPS panels produced by foaming polystyrene with the addition of hydrophobic agents that minimize their water absorption. Designed for thermal insulation, among others. basement walls, parking lots and driveways, terraces and flat roofs.
Product features:
- Code of designation: EPS EN 13163 T(1)-L(2)-W(2)-Sb(5)-P(5)-BS170-CS(10)120-DS(N)2-DS(70,-)1-DLT(1)5-WL(T)4,
- Declared thermal conductivity coefficient λD ≤ 0,035 (W/(mK),
- Standards dimensions tof the panel 1000 x 500 mm. (untypical dimensions on request.),
- Panel thickness: 10 – 500 mm,
- Panels can be produced with straight or milled edges.
APPLICATION OF EPS 035 Terra Aqua Eco

EPS 035 TERRA AQUA ECO polystyrene panels are used for insulation in areas requiring the transfer of high mechanical loads and those in direct contact with the ground, among others:
- insulation of basement walls and foundations as well as socles,
- insulation of parking areas, driveways and terraces under extensive load,
- insulations in road construction, railway construction and civil engineering structures,
- insulation of flat roofs,
- insulation of rooms with high humidity.
DETAILS
EPS 035 Terra Aqua ECo PANEL TECHNICAL SPECIFICATION:
Properties | Class | Required |
Thickness | T(1) | ±1 mm |
Length | L(2) | ±2 mm |
Width | W(2) | ±2 mm |
Rectangularity | Sb(5) | ±5 mm |
Flatness | P(5) | ±5 mm |
Bending strength | BS170 | ≥170 kPa |
Compressive stress at 10% relative deformation | CS(10)120 | ≥120 kPa |
Dimensional stability under constant normal laboratory conditions | DS(N)2 | ±0,2% |
Dimensional stability under specific temperature and humidity conditions | DS(70,-)1 | ≤1% |
Deformation under specific conditions of compressive stress and temperature | DLT(1)5 | ≤5% |
Long term water absorption by total immersion | WL(T)4 | ≤4% |
Reaction-to-fire class | E | |
Declared thermal conductivity coefficient λD | ≤0,035(W/(mK) |
TABLE OF THERMAL RESISTANCE EPS 035 Terra Aqua Eco
Panel thickness (mm) | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
RD(m²K/W) | 0,25 | 0,55 | 0,85 | 1,10 | 1,40 | 1,70 | 2,00 | 2,25 | 2,55 | 2,85 |
Panel thickness (mm) | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
RD(m²K/W) | 3,10 | 3,40 | 3,70 | 4,00 | 4,25 | 4,55 | 4,85 | 5,10 | 5,40 | 5,70 |
Panel thickness (mm) | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD(m²K/W) | 6,00 | 6,25 | 6,55 | 6,85 | 7,10 | 7,40 | 7,70 | 8,00 | 8,25 | 8,55 |
SIMILAR PRODUCTS
EPS 034 Terra Aqua Standard
Insulation panels with thermal conductivity coefficient λD ≤0.034(W/(mK)