EPS 036 ROOF FLOOR SUPER
Application
EPS 036 ROOF FLOOR SUPER polystyrene panels applied in insulations which require shifting of extensive mechanical load, among others:
- insulation of socles in external thermal insulation composite systems ETICS,
- insulation of walls below ground level, with water insulation,
- insulation of floors, attics, converted and unconverted lofts,
- insulation of floors in residential and public utility construction,
- insulation of floors in underfloor heating systems,
- roof insulation in the system of descending wedge,
- insulations of flat and steep roofs over, under and between transoms,
- insulation of terraces and balconies,
Code of designation:
EPS EN 13163 T(1)-L(2)-W(2)-Sb(5)-P(10)-BS150-CS(10)100-DS(N)2-DS(70,-)1
EPS 036 roof floor super panel technical specification:
Properties | Class | Required |
Thickness | T(1) | ±1 mm |
Length | L(2) | ±2 mm |
Width | W(2) | ±2 mm |
Rectangularity | Sb(5) | ±5 mm |
Flatness | P(10) | ±10 mm |
Bending strength | BS150 | ≥150 kPa |
Compressive stress at 10% relative deformation | CS(10)100 | ≥100 kPa |
Dimensional stability under constant normal laboratory conditions | DS(N)2 | ±0,2% |
Dimensional stability under specific temperature and humidity conditions | DS(70,-)1 | ≤1% |
Reaction-to-fire class | E | |
Declared thermal conductivity coefficient λD | ≤0,036(W/(mK) |
Panel thickness: 10 – 500 mm
Panel width: 500 mm
Panel length: 1000 mm
Untypical dimensions on request.
Even or finely-milled edges.
Thermal resistance:
Panel thickness (mm): | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
RD(m²K/W) | 0,25 | 0,55 | 0,80 | 1,10 | 1,35 | 1,65 | 1,90 | 2,20 | 2,50 | 2,75 |
Panel thickness (mm): | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
RD(m²K/W) | 3,05 | 3,30 | 3,60 | 3,85 | 4,15 | 4,40 | 4,70 | 5,00 | 5,25 | 5,55 |
Panel thickness (mm): | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD(m²K/W) | 5,80 | 6,10 | 6,35 | 6,65 | 6,90 | 7,20 | 7,50 | 7,75 | 8,05 | 8,30 |