EPS 040 Standard Facade
Application
EPS 040 STANDARD FACADE polystyrene panels applied in insulations which require shifting of extensive mechanical load, among others:
- Insulation of walls in external thermal insulation composite systems ETICS (light-wet method),
- insulation of multi-layer walls with ventilated and unventilated air gap,
- insulation of tie beams as formwork lost for plaster,
- insulation of windowsill reinforcements and window reveal,
- insulation in external prefabricated sandwich panels,
- insulation of ceiling from below in external thermal insulation composite systems ETICS.
Code of designation:
EPS EN 13163 T(1)-L(2)-W(2)- Sb(5)-P(10)-BS100-DS(N)2-DS(70,-)1-TR100
EPS 040 STANDARD Facade panel technical specification:
Properties | Class | Required |
Thickness | T(1) | ±1 mm |
Length | L(2) | ±2 mm |
Width | W(2) | ±2 mm |
Rectangularity | Sb(5) | ±5 mm |
Flatness | P(10) | ±10 mm |
Bending strength | BS100 | ≥100 kPa |
Dimensional stability under constant normal laboratory conditions | DS(N)2 | ±0,2% |
Dimensional stability under specific temperature and humidity conditions | DS(70,-)1 | ≥1% |
Tensile strength perpendicular to faces | TR100 | ≥ 100 kPa |
Reaction-to-fire class | E | |
Declared thermal conductivity coefficient λD | ≤0,040(W/(mK) |
Panel thickness: 10 – 500 mm
Panel width: 500 mm
Panel length: 1000 mm
Untypical dimensions on request.
Even or finely-milled edges.
Thermal resistance:
Panel thickness (mm): | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
RD(m²K/W) | 0,25 | 0,50 | 0,75 | 1,00 | 1,25 | 1,50 | 1,75 | 2,00 | 2,25 | 2,50 |
Panel thickness (mm): | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
RD(m²K/W) | 2,75 | 3,00 | 3,25 | 3,50 | 3,75 | 4,00 | 4,25 | 4,50 | 4,75 | 5,00 |
Panel thickness (mm): | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD(m²K/W) | 5,25 | 5,50 | 5,75 | 6,00 | 6,25 | 6,50 | 6,75 | 7,00 | 7,25 | 7,50 |