EPS 042 Facade


EPS 042 FACADE

Application

Płyty warstwowe

EPS 042 FACADE polystyrene panels applied in insulations which do not require shifting of extensive mechanical load, among others:
  • Insulation of walls in external thermal insulation composite systems ETICS (light-wet method),
  • insulation of multi-layer walls with ventilated and unventilated air gap,
  • insulation of stud walls with cladding,
  • insulation of ceilings from below,
  • insulation of floors between ground beams,
  • insulation of expansion gaps.

Code of designation:

EPS EN 13163 T(2)-L(3)-W(3)- Sb(5)-P(15)-BS75-DS(N)2-DS(70,-)1-TR80

EPS 042 Facade panel technical specification:

Properties Class Required
Thickness T(2) ±2 mm
Length L(3) ±0,6% lub ±3 mm
Width W(3) ±0,6% lub ±3 mm
Rectangularity Sb(5) ±5 mm
Flatness P(15) ±15 mm
Bending strength BS75 ≥75 kPa
Dimensional stability under constant normal laboratory conditions DS(N)2 ±0,2%
Dimensional stability under specific temperature and humidity conditions DS(70,-)1 ≤1%
Tensile strength perpendicular to faces TR80 ≥ 80 kPa
Reaction-to-fire class E
Declared thermal conductivity coefficient λD ≤0,042(W/(mK)

Panel thickness: 10 – 500 mm
Panel width: 500 mm
Panel length: 1000 mm
Untypical dimensions on request.
Even or finely-milled edges.

Thermal resistance:

Panel thickness (mm): 10 20 30 40 50 60 70 80 90 100
RD(m²K/W) 0,2 0,45 0,70 0,95 1,15 1,40 1,65 1,90 2,10 2,35
Panel thickness (mm): 110 120 130 140 150 160 170 180 190 200
RD(m²K/W) 2,60 2,85 3,05 3,30 3,55 3,80 4,00 4,25 4,50 4,75
Panel thickness (mm): 210 220 230 240 250 260 270 280 290 300
RD(m²K/W) 5,00 5,20 5,45 5,70 5,95 6,15 6,40 6,65 6,90 7,10