EPS ECO FACADE
Application
EPS ECO FACADE polystyrene panels applied in insulations which do not require shifting of extensive mechanical load, among others:
- Insulation of walls in external thermal insulation composite systems ETICS (light-wet method),
- insulation of multi-layer walls with ventilated and unventilated air gap,
- insulation of stud walls with cladding,
- insulation of ceilings from below,
- insulation of floors between ground beams,
- insulation of expansion gaps.
Code of designation:
EPS EN 13163 T(2)-L(3)-W(3)-Sb(5)-P(15)-BS50-DS(N)5-DS(70,-)3-TR80
EPS Eco Facade panel technical specification:
Properties | Class | Required |
Thickness | T(2) | ± 2 mm |
Length | L(3) | ±0,6% lub ±3 mm |
Width | W(3) | ±0,6% lub ±3 mm |
Rectangularity | Sb(5) | ±5 mm |
Flatness | P(15) | ±15 mm |
Bending strength | BS50 | ≥50 kPa |
Dimensional stability under constant normal laboratory conditions | DS(N)5 | ±0,5% |
Dimensional stability under specific temperature and humidity conditions | DS(70,-)3 | ≤3% |
Tensile strength perpendicular to faces | TR80 | ≥ 80 kPa |
Reaction-to-fire class | E | |
Declared thermal conductivity coefficient λD | ≤0,045(W/(mK) |
Panel thickness: 10 – 500 mm
Panel width: 500 mm
Panel length: 1000 mm
Untypical dimensions on request.
Even or finely-milled edges.
Thermal resistance:
Panel thickness (mm): | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
RD(m²K/W) | 0,2 | 0,40 | 0,65 | 0,85 | 1,10 | 1,30 | 1,55 | 1,75 | 2,00 | 2,20 |
Panel thickness (mm): | 110 | 120 | 130 | 140 | 150 | 160 | 170 | 180 | 190 | 200 |
RD(m²K/W) | 2,40 | 2,65 | 2,85 | 3,10 | 3,30 | 3,50 | 3,75 | 4,00 | 4,20 | 4,40 |
Panel thickness (mm): | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD(m²K/W) | 4,65 | 4,85 | 5,10 | 5,30 | 5,55 | 5,75 | 6,00 | 6,20 | 6,40 | 6,65 |