ECO FACADE


EPS ECO FACADE

Application

Płyty warstwowe

EPS ECO FACADE polystyrene panels applied in insulations which do not require shifting of extensive mechanical load, among others:
  • Insulation of walls in external thermal insulation composite systems ETICS (light-wet method),
  • insulation of multi-layer walls with ventilated and unventilated air gap,
  • insulation of stud walls with cladding,
  • insulation of ceilings from below,
  • insulation of floors between ground beams,
  • insulation of expansion gaps.

 

Code of designation:

EPS EN 13163 T(2)-L(3)-W(3)-Sb(5)-P(15)-BS50-DS(N)5-DS(70,-)3-TR80

 

EPS Eco Facade panel technical specification:

Properties Class Required
Thickness T(2) ± 2 mm
Length L(3) ±0,6% lub ±3 mm
Width W(3) ±0,6% lub ±3 mm
Rectangularity Sb(5) ±5 mm
Flatness P(15) ±15 mm
Bending strength BS50 ≥50 kPa
Dimensional stability under constant normal laboratory conditions DS(N)5 ±0,5%
Dimensional stability under specific temperature and humidity conditions DS(70,-)3 ≤3%
Tensile strength perpendicular to faces TR80 ≥ 80 kPa
Reaction-to-fire class E
Declared thermal conductivity coefficient λD ≤0,045(W/(mK)

Panel thickness: 10 – 500 mm
Panel width: 500 mm
Panel length: 1000 mm
Untypical dimensions on request.
Even or finely-milled edges.

Thermal resistance:

Panel thickness (mm): 10 20 30 40 50 60 70 80 90 100
RD(m²K/W) 0,2 0,40 0,65 0,85 1,10 1,30 1,55 1,75 2,00 2,20
Panel thickness (mm): 110 120 130 140 150 160 170 180 190 200
RD(m²K/W) 2,40 2,65 2,85 3,10 3,30 3,50 3,75 4,00 4,20 4,40
Panel thickness (mm): 210 220 230 240 250 260 270 280 290 300
RD(m²K/W) 4,65 4,85 5,10 5,30 5,55 5,75 6,00 6,20 6,40 6,65